Cooling Tunnel:-
Technical Specifications
1. Section  Ist  
a) Filled Bottom Temp:- 80º - 85º C
b) Hot water circulation Temp.:- 60- 65º C
c) Bottle outgoing Temp.:- 65 - 70º C
2. Section 2nd    
1. Incoming Bottle Temp.:- 65 - 70º C
2. Water circulation Temp.:- 40- 45º C
3. Bottle outgoing Temp.:- 45- 50º C
3. Section 3rd  
1. Incoming Bottom Temp.:- 45- 50º C
2. Water circulation Temp.:- 35- 40º C
3. Cooling Tower water inlet Temp.:- 30-32º C
4. Bottle outgoing Temp.:- 38 - 45º C
Tunnel Consists of following:-     
a) S.S. Frame work with legs.
b) PP belt with Nylon Sprockets.
c) S.S. Drive & Driven Shaft with bearings
d) S.S. Rectangular Tank, 03 Sections for water Recirculation.
e) Ist Section will have  water circulation. 
f) 03 Nos. S.S. Pump for water Circulation.
g) S.S. PHE 01 Unit for Cooling of recirculation water by means of cooling tower water.    
h) S.S. Interconnecting Pipe lines, fittings, Valves & etc.
  

Item

Cooling Tunnel

Size:

1.5 m x 6.5 Mtr. long.

No. of Section

03 Nos.

Feeding & Discharge Height:

900 -1000 mm Ht.

Power

2.2kw